Uji Validitas Isi dan Reliabilitas Konsistensi Internal Instrumen Pediatric Confusion Assessment Method Intensive Care Unit (pCAMICU) versi Bahasa Indonesia = Content Validity and Internal Consistency Reliability Test for Indonesian version of Pediatric Confusion Assessment Method Intensive Care Unit (pCAM-ICU).

Latar Belakang: Delirium adalah perubahan status mental berupa gangguan atensi, kesadaran, dan kognisi yang akut dan fluktuatif. Referensi standar mendiagnosis delirium pada anak dan dewasa menggunakan kriteria DSM-5 atau ICD-10. Populasi anak memiliki tahap perkembangan dan gambaran gejala delirium yang berbeda dibandingkan dewasa sehingga diagnosis delirium anak mengalami keterbatasan dan membutuhkan kemampuan klinis dan kompetensi. Telah dikembangkan instrumen pCAM-ICU untuk membantu diagnosis delirium anak usia minimal lima tahun yang memiliki sensitivitas dan spesifisitas yang tinggi. Saat ini pelayanan kesehatan anak di Indonesia belum memiliki instrumen membantu diagnosis delirium dalam Bahasa Indonesia. Oleh karena tingginya kebutuhan pelayanan, maka dilakukan validitas isi dan reliabilitas konsistensi internal instrumen pCAM-ICU versi Bahasa Indonesia Metode: Dilakukan proses forward translation dan back translation hingga didapatkan instrumen pCAM-ICU versi Bahasa Indonesia. Uji validitas isi pCAMICU versi Bahasa Indonesia melibatkan 10 orang ahli di Ilmu Kesehatan Jiwa dan Ilmu Kesehatan Anak yang pernah menangani kasus delirium pada anak dan remaja. Uji reliabilitas konsistensi internal dilakukan pada 30 pasien anak yang berusia 5 – 17 tahun di layanan RSCM. Penelitian ini merupakan penelitian potong lintang dengan membandingkan pemeriksaan pCAM-ICU dengan kriteria DSM-5. Hasil: Instrumen pCAM-ICU versi bahasa Indonesia memiliki nilai I-CVI dan S-CVI sebesar 1,00 pada uji validitas isi dan Cronbach’s alpha keseluruhan 0,959 pada uji reliabilitas konsistensi internal. Instrumen pCAM-ICU versi Bahasa Indonesia memiliki nilai sensitivitas 85% (95% CI, 68-100%) dan spesifisitas 96% (95% CI, 86- 100%) Simpulan: Instrumen pCAM-ICU versi Bahasa Indonesia dinilai valid dan reliabel dalam membantu penegakkan diagnosis delirium pada anak minimal usia lima tahun
Kata kunci: Delirium anak, instrumen pCAM-ICU, validitas, reliabilitas


Background: Delirium is defined as an acute and fluctuating altered mental status in the form disruption of attention, consciousness, and cognition. DSM-5 and ICD-10 criteria are used as a standardized reference to diagnose delirium. Pediatric population has a different developmental stage and clinical manifestation compared to adult population, hence diagnosing delirium in pediatric population is limited and requires further clinical skill and competence. pCAM-ICU has been developed to help diagnosing delirium for children at least 5 years old with high sensitivity and specificity. Pediatric healthcare service in Indonesia does not have an instrument to help diagnosing delirium in Bahasa Indonesia. Due to the need of such instruments, content validation and internal consistency reliability test for Indonesian version of pCAM-ICU is carried out. Methods: Forward translation and back translation is carried out to obtain the Indonesian version of pCAM-ICU. Content validity of Indonesian pCAM-ICU involves 10 experts in Psychiatry and Pediatric who have managed delirium cases in children and adolescent. Internal consistency reliability test is done to 30 pediatric populations from the age of 5-17 years old in RSCM. This research is a cross sectional research which compares pCAM-ICU with DSM-5 criteria. Results: Indonesian version of pCAM-ICU has I-CVI and S-CVI score of 1,00 at content validity test and overall Cronbach’s alpha of 0,959 for internal consistency reliability test. Indonesian version of pCAM-ICU has 85% (95% CI, 68-100%) sensitivity and 96% (95% CI, 86-100%) specificity. Conclusion: Indonesian version of pCAM-ICU is considered valid and reliable to held diagnosing delirium in children of at least 5 years old.
Keywords: Pediatric delirium, pCAM-ICU instrument, validity, reliability.

Judul Seri
-
Tahun Terbit
2023
Pengarang

Maria Veronika Prescillia Hartanuh - Nama Orang
Fransiska Kaligis - Nama Orang
Antonius Hocky Pudjiadi - Nama Orang
Raden Irawati Ismail - Nama Orang

No. Panggil
T23364fk
Penerbit
Jakarta : Program Pendidikan Dokter Spesialis Bidang Studi Ilmu Kedokteran Jiwa.,
Deskripsi Fisik
xvi, 71 hlm. ; 21x 30 cm
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
NONE
Edisi
-
Subjek
Info Detail Spesifik
Tanpa Hardcopy
T23364fkT23364fkPerpustakaan FKUITersedia
Image of Uji Validitas Isi dan Reliabilitas Konsistensi Internal Instrumen Pediatric Confusion Assessment Method Intensive Care Unit (pCAMICU) versi Bahasa Indonesia = Content Validity and Internal Consistency Reliability Test for Indonesian version of Pediatric Confusion Assessment Method Intensive Care Unit (pCAM-ICU).

Related Collection